RFE - SERIES - TANK
DEPRESSURIZED
This
control should be considered when stopping will occur infrequently or when a
hopper fill is used and machine filling is done remotely.
OPERATION:
Releasing the control
activating switch (deadman) closes the inlet valve to the supply air and
simultaneously opens the exhaust valve causing the tank to
depressurize. Restart is accomplished by closing the deadman
switch. This closes the exhaust valve and opens the inlet valve
restoring pressure to the tank. Blasting will stop or start within
1/2-3 seconds of switch activation in either mode depending upon tank
volume and distance from the machine to the deadman.
RFE-1
All models with pipe size through 1"
RFE-14 All models with pipe size through 1-1/2"
Field installation kits for
older Titan and other machines available for both systems.
|